• youtube
  • Tiktok
  • Linkedin
  • Facebook
  • Twitter
company

WesternFlag – DL2 Electric Heater (Left-right alternating circulation)

Short Description:


  • Heat sources: Electrical
  • Usage: To heating dryers, boilers, greenhouse, oil well, etc.
  • Circulation mode: Left and right alterating
  • Service: OEM, ODM, Private Label
  • MOQ: 1
  • Material: Steel, SS201, SS304 optional
  • Temperature range: Atmospheric temperature-200℃, customized
  • Air volume: 15000-48000m³/h, customized
  • Power: 52-154KW, 380V, 3N
  • Product Detail

    Product Tags

    Product Overview

    Heat source : Electric

    Airflow direction: Left-Right Circulation

    Matching Drying Room : HH Series Tray Type Drying Rooms

    Features : Multi axial circulation fans for large air volume | Stable left-right horizontal airflow | Even heat distribution| Adjustable fan rotation direction for air supply & return

    https://www.dryequipmfr.com/the-red-fire-t-series-natural-gas-drying-room-product/
    https://www.dryequipmfr.com/the-red-fire-t-series-natural-gas-drying-room-product/
    Chenpi
    https://dryequipmfr.com/
    https://dryequipmfr.com/
    https://dryequipmfr.com/

    Advantages

    1. Straightforward arrangement and effortless setup.
    2. Considerable air flow and minor wind temperature variation.
    3. Long-lasting stainless steel electric heating finned tube.
    4. Automated operating mechanism, group start and stop, small load, accurate temperature regulation
    5. High-density fireproof rock wool insulation box to prevent heat loss.
    6. Fan resistant to high temperature and high humidity with IP54 safeguard rating and H-class insulation rating.
    7. Left and right blower function alternately in cycles to ensure uniform heating.
    8. Automatically add fresh air.

    Real photos

    https://www.dryequipmfr.com/
    https://www.dryequipmfr.com/
    https://www.dryequipmfr.com/

    Working Schematic Diagram

    1. DL2 Series electric hot blast furnace is composed of fans, electric air valve and electric heater.

    2. Cold air enters through the electric air valve, then passes through the electric heater for heating.

    3. Multiple‑fan layout delivers high‑temperature air evenly to target areas.

    4. Internal airflow circulates inside the unit to ensure stable temperature output.

    5. It delivers clean hot air, suitable for scenarios requiring stable and even heat supply.

    1706162317085

    Specifications

    Model DL2 (Left-right circulation) Output heat (×104Kcal/h) Output temperature (℃) Output air volume (m³/h) Weight (KG) Dimension (mm) Power (KW) Material Heat exchange mode Energy Voltage Electrothermal power Parts Applications
    DL2-5 electric heater 5 Normal temperature -100 4000--20000 380 1160*1800*2000 48+3.4 1.Stainless steel electric heating finned tube2.High-density fire-resistant rock wool for box3.Sheet metal parts are sprayed with plastic; remaining carbon steel4.Can be customized by your requirements Heating by electric heating tube Electricity 380V 48 1. 4 groups of electric heaters2. 6-12 pcs circulating fans3. 1 pcs furnace body4. 1 pcs electric control box 1. Supporting drying room, dryer and drying bed.2, Vegetables, flowers and other planting greenhouses3, Chickens, ducks, pigs, cows and other brooding rooms4, workshop, shopping mall, mine heating5. Plastic spraying, sand blasting and spray booth6. And more
    DL2-10electric heater 10 450 1160*2800*2000 96+6.7 96
    DL2-20electric heater 20 520 1160*3800*2000 192+10 192
    30, 40, 50, 100 and above can be customized.                          

  • Previous: